Upgrade etcd from 3.1 to 3.2
In the general case, upgrading from etcd 3.1 to 3.2 can be a zero-downtime, rolling upgrade:
- one by one, stop the etcd v3.1 processes and replace them with etcd v3.2 processes
- after running all v3.2 processes, new features in v3.2 are available to the cluster
Before starting an upgrade , read through the rest of this guide to prepare.
Upgrade checklists
When migrating from v2 with no v3 data
, etcd server v3.2+ panics when etcd restores from existing snapshots but no v3 ETCD_DATA_DIR/member/snap/db file. This happens when the server had migrated from v2 with no previous v3 data. This also prevents accidental v3 data loss (e.g. db file might have been moved). etcd requires that post v3 migration can only happen with v3 data. Do not upgrade to newer v3 versions until v3.0 server contains v3 data.
Highlighted breaking changes in 3.2.
Changed default snapshot-count value
Higher --snapshot-count holds more Raft entries in memory until snapshot, thus causing recurrent higher memory usage
. Since leader retains latest Raft entries for longer, a slow follower has more time to catch up before leader snapshot. --snapshot-count is a tradeoff between higher memory usage and better availabilities of slow followers.
Since v3.2, the default value of --snapshot-count has changed from from 10,000 to 100,000
.
Changed gRPC dependency (>=3.2.10)
3.2.10 or later now requires grpc/grpc-go
v1.7.5 (<=3.2.9 requires v1.2.1).
Deprecated grpclog.Logger
grpclog.Logger has been deprecated in favor of grpclog.LoggerV2
. clientv3.Logger is now grpclog.LoggerV2.
Before
After
Deprecated grpc.ErrClientConnTimeout
Previously, grpc.ErrClientConnTimeout error is returned on client dial time-outs. 3.2 instead returns context.DeadlineExceeded (see #8504
).
Before
After
Changed maximum request size limits (>=3.2.10)
3.2.10 and 3.2.11 allow custom request size limits in server side. >=3.2.12 allows custom request size limits for both server and client side. In previous versions(v3.2.10, v3.2.11), client response size was limited to only 4 MiB.
Server-side request limits can be configured with --max-request-bytes flag:
Or configure embed.Config.MaxRequestBytes field:
If not specified, server-side limit defaults to 1.5 MiB.
Client-side request limits must be configured based on server-side limits.
If not specified, client-side send limit defaults to 2 MiB (1.5 MiB + gRPC overhead bytes) and receive limit to math.MaxInt32. Please see clientv3 godoc
for more detail.
Changed raw gRPC client wrappers
3.2.12 or later changes the function signatures of clientv3 gRPC client wrapper. This change was needed to support custom grpc.CallOption on message size limits
.
Before and after
Changed clientv3.Lease.TimeToLive API
Previously, clientv3.Lease.TimeToLive API returned lease.ErrLeaseNotFound on non-existent lease ID. 3.2 instead returns TTL=-1 in its response and no error (see #7305
).
Before
After
Moved clientv3.NewFromConfigFile to clientv3.yaml.NewConfig
clientv3.NewFromConfigFile is moved to yaml.NewConfig.
Before
After
Change in --listen-peer-urls and --listen-client-urls
3.2 now rejects domains names for --listen-peer-urls and --listen-client-urls (3.1 only prints out warnings), since domain name is invalid for network interface binding. Make sure that those URLs are properly formatted as scheme://IP:port.
See issue #6336 for more contexts.
Server upgrade checklists
Upgrade requirements
To upgrade an existing etcd deployment to 3.2, the running cluster must be 3.1 or greater. If it’s before 3.1, please upgrade to 3.1 before upgrading to 3.2.
Also, to ensure a smooth rolling upgrade, the running cluster must be healthy. Check the health of the cluster by using the etcdctl endpoint health command before proceeding.
Preparation
Before upgrading etcd, always test the services relying on etcd in a staging environment before deploying the upgrade to the production environment.
Before beginning, backup the etcd data
. Should something go wrong with the upgrade, it is possible to use this backup to downgrade
back to existing etcd version. Please note that the snapshot command only backs up the v3 data. For v2 data, see backing up v2 datastore
.
Mixed versions
While upgrading, an etcd cluster supports mixed versions of etcd members, and operates with the protocol of the lowest common version. The cluster is only considered upgraded once all of its members are upgraded to version 3.2. Internally, etcd members negotiate with each other to determine the overall cluster version, which controls the reported version and the supported features.
Limitations
Note: If the cluster only has v3 data and no v2 data, it is not subject to this limitation.
If the cluster is serving a v2 data set larger than 50MB, each newly upgraded member may take up to two minutes to catch up with the existing cluster. Check the size of a recent snapshot to estimate the total data size. In other words, it is safest to wait for 2 minutes between upgrading each member.
For a much larger total data size, 100MB or more , this one-time process might take even more time. Administrators of very large etcd clusters of this magnitude can feel free to contact the etcd team before upgrading, and we’ll be happy to provide advice on the procedure.
Downgrade
If all members have been upgraded to v3.2, the cluster will be upgraded to v3.2, and downgrade from this completed state is not possible. If any single member is still v3.1, however, the cluster and its operations remains “v3.1”, and it is possible from this mixed cluster state to return to using a v3.1 etcd binary on all members.
Please backup the data directory of all etcd members to make downgrading the cluster possible even after it has been completely upgraded.
Upgrade procedure
This example shows how to upgrade a 3-member v3.1 etcd cluster running on a local machine.
1. Check upgrade requirements
Is the cluster healthy and running v3.1.x?
2. Stop the existing etcd process
When each etcd process is stopped, expected errors will be logged by other cluster members. This is normal since a cluster member connection has been (temporarily) broken:
It’s a good idea at this point to backup the etcd data to provide a downgrade path should any problems occur:
3. Drop-in etcd v3.2 binary and start the new etcd process
The new v3.2 etcd will publish its information to the cluster:
Verify that each member, and then the entire cluster, becomes healthy with the new v3.2 etcd binary:
Upgraded members will log warnings like the following until the entire cluster is upgraded. This is expected and will cease after all etcd cluster members are upgraded to v3.2:
4. Repeat step 2 to step 3 for all other members
5. Finish
When all members are upgraded, the cluster will report upgrading to 3.2 successfully: